The West Jordan City Building & Safety Division uses the following design criteria when reviewing projects submitted for a building permit within City limits.
-
BUILDING CODES: The Building Division enforces the following building codes with State of Utah amendments.
- 2024 International Building Code (including Appendices C & J)
- 2021 International Residential Code (including Appendix AQ)
- 2024 International Plumbing Code
- 2024 International Mechanical Code
- 2024 International Fuel Gas Code
- 2023 National Electric Code
- 2024 International Energy Conservation Code
- 2024 International Existing Building Code
- 2024 International Swimming Pool and Spa Code (residential provisions only)
- 2024 International Fire Code
- ICC A117.1-2009 – Accessibility Standard
- City of West Jordan – Title 10 Building Regulations
-
SNOW LOADS:
- Residential: The ground snow loads shall be determined using the following website: https://utahsnowload.usu.edu
- Commercial: The ground snow loads shall be determined using the ASCE Hazard Tool: https://ascehazardtool.org/
-
Roof Snow Loads:
- Shall be determined per Chapter 7 of ASCE 7-22.
- At locations where the roof snow load exceeds 45 psf, a percentage of the snow load must be considered in the effective seismic weight of the structure per Section 15A-3-107 of the Utah Amended Code.
-
WIND:
-
Speed: All wind speeds listed below are 3-second gusts at 33 feet above the ground.
- Residential: 105 mph
- Commercial (see IBC Figures 1609.3(1–4)):
- Risk Category I = 95–100 mph (see IBC Figure 1609.3(1))
- Risk Category II = 100–105 mph (see IBC Figure 1609.3(2))
- Risk Category III = 105–110 mph (see IBC Figure 1609.3(3))
- Risk Category IV = 110–115 mph (see IBC Figure 1609.3(4))
- Exposure: Site specific (per Section 1609.4 of the IBC). Assumed to be “C” unless justified.
-
Speed: All wind speeds listed below are 3-second gusts at 33 feet above the ground.
-
SEISMIC:
- Seismic Design Category:
- Residential: D2
- Commercial: D
- Site-specific: Because ground motions vary throughout the city, the mapped and design ground motions (SS, SDS, S1, SD1) should be obtained using the site-specific address or latitude/longitude in the ASCE Hazard Tool: https://ascehazardtool.org/
- Seismic Design Category:
-
SOILS:
- Frost Depth: 30 inches.
- Site Class: Site specific. See geotechnical report for site class.
- Residential: 1,500 psf per IRC Table R401.4.1, unless stated otherwise in a geotechnical report.
- Commercial: Site-specific geotechnical report required for all new buildings.
- Site-specific Geotechnical Report: All geotechnical reports submitted for permit issuance must be dated no later than two years from the permit application date. Outdated reports must be accompanied by a letter from a qualified geotechnical engineer stating that the report requirements are still valid or explaining what items may have changed.
-
FLOOD HAZARDS:
-
Flood Hazard Areas:
- Residential: Buildings and structures located in flood hazard areas (Flood Zones A or V) must comply with IRC R322.
- Commercial: Buildings and structures located in flood hazard areas must comply with IBC 1612, Chapter 5 of ASCE 7-22, and ASCE 24-14.
- Floodways: Buildings and structures located in identified floodways must be designed and constructed in accordance with ASCE 24-14.
- Interactive Flood Zone Map:
https://gis.wjordan.com/flood-zones/
-
Flood Hazard Areas:
- RAINFALL: Average annual rainfall is 16 inches.
- CLIMATE ZONE: 5B
- WEATHERING: Severe
- TERMITE: None to Slight
- WINTER DESIGN TEMP: 8°F
- ICE SHIELD UNDERLAYMENT: Yes
- AIR FREEZING INDEX: ≤ 1000
- MEAN ANNUAL TEMP: 45°F
Last Revised: 07/2026